Variables in the default:control_monitor context are automatically created from attributes defined in body monitor control following the pattern default:default:control_monitor.<attribute>.

default:control_monitor.forgetrate

Controls the rate at which cf-monitord forgets historical monitoring data. A value between 0 and 1 determines how quickly older observations decay in significance.

See also: forgetrate in body monitor control

default:control_monitor.histograms

Determines whether cf-monitord should generate histograms for monitoring data. Setting this to true enables histogram-based data collection.

See also: histograms in body monitor control

default:control_monitor.monitorfacility

Controls the syslog facility level used by cf-monitord. Valid values are LOG_USER, LOG_DAEMON, LOG_LOCAL0 through LOG_LOCAL7.

See also: monitorfacility in body monitor control

default:control_monitor.tcpdump

Enables or disables tcpdump-based network monitoring in cf-monitord.

See also: tcpdump in body monitor control

default:control_monitor.tcpdumpcommand

Specifies the command used for tcpdump-based network monitoring when tcpdump is enabled.

See also: tcpdumpcommand in body monitor control